Module features and uses
1. Implement high-frequency, fast, and frequent on-off of the circuit, with unlimited switching times;
2. The on-off process will not produce noise, no electric sparks, and no electromagnetic interference;
3. The service life is longer than that of commonly used electromagnetic relays;
4. Adopting dual MOS parallel active output, the internal resistance is lower, the current is higher, and the power is strong. At room temperature, it is 15A and 400W, which meets the needs of most devices;
5. Often used to control motors, light bulbs, LED light strips, DC motors, miniature water pumps, solenoid valves, etc. can be easily controlled through this module, which is very convenient.
Module highlights
1. Wide voltage operation (5-36V), most devices can be used, very convenient;
2. Clear and simple interface, powerful functions, easy to understand, almost meeting all your needs;
3. It has a one button emergency stop function (STOP button), with reverse connection protection, and reverse connection does not burn;
4. Different OP, CL, and LOP parameters can be set, which are independent of each other and saved separately;
5. All setting parameters will be automatically powered off and saved.
Product Pin Definition
Working mode:
P1 mode: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, perform the following operations
P1.1: Signal triggered again is invalid
P1.2: Signal triggered again, re timed
P1.3: Signal triggers reset again, relay disconnects, and timing stops;
P-2: Give a trigger signal, after the relay disconnects the CL time, the relay conducts the OP time, and after the timing is completed, disconnect the relay;
P3.1: Give the trigger signal, after the relay conducts OP time, the relay disconnects CL time, and then cycles the above actions. Within the cycle, give the signal again, the relay disconnects, and the timer stops; The number of loops (LOP) can be set;
P3.2: After power on, there is no need to trigger a signal. The relay conducts OP time and disconnects CL time, and the above actions are repeated; The number of loops (LOP) can be set;
P-4: If there is a trigger signal for the signal holding function, the timer will be reset and the relay will remain conductive; When the signal disappears, disconnect the relay after timing OP; During the timing period, if there is a signal again, the timing will be reset to zero;
Product parameters
1: Working voltage: DC 5V--36V;
2: Trigger signal source: High level trigger (DC 3.0V-24V) signal ground is not common with system ground to improve the anti-interference ability of the system (it can also be self short circuited to common ground)
3: Output capability: DC 5V-36V, continuous current 15A at room temperature, power 400W! Under auxiliary heat dissipation conditions, the current can reach 30A.
4: Static current: 15mA
5: Service life: unlimited switching; Working temperature: -40-85 ℃; Size: 6.0 * 3.4 * 1.2cm
6: Equipped with optocoupler isolation to enhance anti-interference ability, industrial grade circuit board, set parameters to be permanently remembered after power failure.
Special attention
The module is an active live output, and the voltage at the output terminal (load terminal) is equal to the voltage at the input terminal (DC 5V --36V).
The 'DC+' and load '+' poles are inherently short circuited internally, but the 'DC -' and load '-' poles cannot be short circuited during use, otherwise the load cannot be controlled to turn on and off, which is equivalent to the load being constantly powered on.
Timing range
0.1 seconds (small)~999 minutes (continuous adjustable)
How to choose a timing range:
After setting the parameter values on the mode selection interface, short press the STOP button to select the timing range;
XXX. The decimal point is in units, and the timing range is 1 second to 999 seconds
XX.X The decimal point of X is in ten places, and the timing range is 0.1 seconds to 99.9 seconds
X. X.X. decimal point fully lit, timing range: 1 minute to 999 minutes
For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten and the digital display will show 03.2
Parameter description: OP conduction time, CL disconnection time, LOP cycle times (1-999 times, "---" represents infinite cycles)
These parameters are independent of each other, but they are shared among different modes. For example, in P1.1, the conduction time OP is set to 5 seconds. If the user wants to switch to P1.2 mode, when entering P1.2 to set the corresponding parameters, the OP will also be 5 seconds;
Short press the SET button on the main interface (display 000) to display OP (CL, LOP) and the corresponding time XXX;
If there is only OP time in the mode (such as mode P1.1, P1.2, P1.3), pressing the SET key briefly will only display OP and corresponding time;
If there are OP, CL, LOP in the mode (such as mode P3.1, P3.2), short pressing the SET key will display OP and corresponding time, CL and corresponding time, LOP and corresponding number of times;
After setting the mode, you can easily view the parameters set in the current mode by short pressing the SET key on the main interface, which is very convenient!
Product Settings
How to set parameters
1. determine the working mode of the relay;
2. According to the working mode of the relay, on the main interface (when the module is powered on, it will flash the current working mode (default P1.1 mode), and then enter the main interface), press and hold the SET button for 2 seconds and then release it to enter the mode selection interface. Short press the UP and DOWN buttons to select the mode to be set (P1.1~P-4);
3. After selecting the mode to be set (e.g. P3.2), press the SET key briefly to set the corresponding parameters. At this time, the parameters to be set will flash (OP conduction time, CL disconnection time, LOP cycle times ("---" represents infinite cycles)). Adjust the parameter values through UP and DOWN, and support long press (quick increase or decrease) and short press (increase or decrease by 1 unit); After setting the parameter values, short press the STOP key to select the decimal point position and choose the timing range (corresponding time from 0.1 seconds to 999 minutes); Short press the SET key to set the next parameter for the current mode, the process is the same as above;
After setting the parameters for the selected mode, press and hold the SET button for 2 seconds before releasing it. The currently set mode will flash and then return to the main interface. Setting the parameters is successful, very simple!
Main interface: When the relay is not working, it displays "000" (without a decimal point). When the relay is working, it has a decimal point, which is very clear!
Mode selection interface: Press and hold the SET key to enter. After setting is complete, press and hold the SET key to exit and return to the main interface. It's very simple!
STOP button function extension:
Relay enable mode:
1. ON: The relay is allowed to conduct during the OP conduction time;
2. OFF: The relay is prohibited from conducting and remains in a closed state;
Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, and then return to the main interface. (This function is an emergency stop function, a relay that can be opened and closed with one click)
Product Show
Payment&Transportation
Official Certificate&Certificate
Multiple product supply
Company office environment
Warehouse Real Shot
Standard packaging
We also provide :
Part No | Manufacturer | Date Code | Quantity | Description |
LM22676ADJ | NS | 19+ | 250 | SOP8 |
TPS562201DDCR | TI | 22+ | 795500 | SOT23-6 |
NJG1806K75 | JRC | 22+ | 500000 | DFN6 |
TLV74318PDQNR | TI | 22+ | 402000 | X2SON-4 |
NJG1801K75 | JRC | 22+ | 300000 | SMD |
NJG1804K64 | JRC | 22+ | 300000 | DFN8 |
LM27761DSGR | TI | 22+ | 151000 | WSON8 |
TLV62565DBVR | TI | 22+ | 138000 | SOT23-5 |
TPS613222ADBVR | TI | 22+ | 108000 | SOT23-5 |
LNK625DG-TL | POWER | 22+ | 100000 | SOP-8 |
OPA4322AIPWR | TI | 22+ | 100000 | TSSOP14 |
TLV75528PDRVR | TI | 22+ | 99000 | WSON-6 |
TPS7A2025PDQNR | TI | 22+ | 78500 | X2SON-4 |
TLV62568DBVR | TI | 22+ | 72000 | SOT23-5 |
STM32L051K8U6TR | ST | 22+ | 60000 | QFN32 |
SKY66421-11 | SKYWORKS | 22+ | 56500 | QFN16 |
TPS7A1111PDRVR | TI | 22+ | 54000 | WSON6 |
TLV62569PDDCR | TI | 22+ | 52000 | SOT23-6 |
TLV62569DBVR | TI | 22+ | 48000 | SOT23-5 |
TPS23753APWR | TI | 22+ | 40000 | TSSOP14 |
NB691GG-Z | MPS | 22+ | 30000 | QFN |
SN74AHC1G02DBVR | TI | 22+ | 27939 | SOT-23 |
TPS63000DRCR | TI | 22+ | 23238 | VSON10 |
TLV75533PDRVR | TI | 22+ | 21500 | WSON6 |
NB687BGQ-Z | MPS | 22+ | 20000 | QFN |
A3916GESTR-T-1 | ALLEGRO | 22+ | 17150 | QFN-20 |
TPS62135RGXR | TI | 22+ | 15000 | VQFN11 |
TLE2022AMDR | TI | 0803+ | 12500 | SOP8 |
TPS23756PWPR | TI | 22+ | 12000 | HTSSOP-20 |