Relay module delay power-off disconnection triggering delay cycle timing circuit switch XY-LJ02

XY-LJ02

Model:XY-LJ02

Manufacturer:ANSC/OEM

Package:module

Detail

Product parameters


1: Working voltage: 6-30V, supports MICRO USB 5.0V power supply


2: Trigger signal source: high-level trigger (3.0V~24V), low-level trigger (0.0V~0.2V), switch quantity control (passive switch).


3: Output capability: Can control devices within 30V5A DC or 220V5A AC


4: Static current: 15MA Working current: 50mA


5: Service life: over 100000 cycles; Working temperature: -40-85 ° C; Size: 8.0 * 3.8 * 1.9CM


6. Equipped with optocoupler isolation to enhance anti-interference ability, industrial grade circuit board, set parameters to be permanently remembered after power failure.


Product highlights


1. Equipped with LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;


2. Supports high and low level triggering, controlled by switches, suitable for most occasions;


3. Wide voltage power supply (6-30V) supports micro USB 5.0V power supply, making it very convenient to use;


4. Support UART data upload and parameter settings;


5. It has a one button emergency stop function (STOP button), with reverse connection protection, and reverse connection does not burn out;


6. Added sleep mode, which automatically turns off the LCD backlight within 5 minutes without any operation after enabling it; Wake up with any button;


7. Different OP, CL, and LOP parameters can be set, which are independent of each other and saved separately;


8. All setting parameters will be automatically powered off and saved.


Product Use


Circuit construction


1. Prepare accessories, DC power supply, several wires, and control equipment needed

未标题-1

2. Circuit connection


The following diagram shows the connection of weak current to strong current. The working voltage can be supplied by Micro UsB5V or by terminals 6-30V

详情-09

The following diagram shows the connection of the control equipment and module working voltage sharing the same power supply, ensuring that the power supply voltage is between 6V~30V

详情-10

Working mode:


P1: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal is triggered again and becomes invalid;


P2: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal triggers a new timer again;


P3: After the signal is triggered, the relay conducts for OP time and then disconnects; During the OP time, the signal triggers a reset again, the relay disconnects, and the timing stops;


P4: Give the trigger signal, after the relay disconnects the CL time, the relay conducts the OP time, and the timer is complete, After completion, disconnect the relay;


P5: Give the trigger signal, after the relay conducts OP time, the relay disconnects CL time, and then cycles the above actions. Within the cycle, give the signal again, the relay disconnects, and the timer stops; The number of loops (LOP) can be set;


P6: After power on, there is no need to trigger a signal. The relay conducts OP time and disconnects CL time, and the above actions are repeated; The number of loops (LOP) can be set;


P7: If there is a trigger signal for the signal holding function, the timer will be reset and the relay will remain conductive; When the signal disappears, disconnect the relay after timing OP; During the timing period, if there is a signal again, the timing will be reset to zero;


Product Timing range


0.01 seconds (minimum)~9999 minutes (maximum) continuously adjustable



How to choose a timing range:


In the OP/CL parameter modification interface, short press the STOP button to select the timing range;


XXXX has no decimal point, with a timing range of 1 second to 9999 seconds


XXX. The decimal point of X is in ten places, with a timing range of 0.1 seconds to 999.9 seconds


XX. XX decimal point in hundreds, timing range 0.01 seconds~99.99 seconds


X. X.X.X decimal point fully lit, timing range 1 minute to 9999 minutes


For example, if you want to set the OP to 3.2 seconds, move the decimal point to ten and the LCD will display 003.2


Parameter description: OP conduction time, CL disconnection time, LOP cycle times (1-9999 times, "----" represents Infinite loops)


Product Parameter settings


a) Press and hold the SET key to enter the settings interface;


b) Firstly, set the working mode, which flashes as a reminder. Set the working mode by short pressing the UP/DOWN keys;


c) Short press the SET button to select the working mode and enter the system parameter settings;


d) In the system parameter setting interface, short press the SET key to switch the system parameters to be modified, and short/long press the UP/DOWN keys to modify them;


(Note: Short press SET is invalid in P-1~P3, P-7 modes):


e) In the OP/CL parameter modification interface, short press STOP to switch the timing unit (1s/0.1s/0.01s/1min);


f) All parameter settings are completed. Long press the SET key to save the parameter settings and exit the settings interface,



4 Remote data upload and parameter setting function


The system supports UART data upload and parameter setting function (TTL level);


UART:9600,8,1


命令
Command
功能
Function
read读取系统参数
Read system parameters
op:xxxx1s
op:xxx.x0.1s
op:xx.xx0.01s
op:x.x.x.x1 min
Cl:xxxx1s
Cl:xxx.x0.1s
Cl:xx.xx0.01s
Cl:x.x.x.x1 min
LP:xxxx循环次数
Number of cycles
ON开启继电器功能
Activate relay function
OFF关闭继电器功能
Turn off the relay function
PX设置模式P1,P2等
Set modes P1, P2, etc


Additional features


a) Automatic sleep function: In the running interface, long press the STOP button to turn on or off the automatic sleep function (L-P selection on will activate the sleep function, off will deactivate the sleep function);


b) Relay function selection: In the operation interface, short press the STOP button to activate or deactivate the relay function The relay is conducting normally when the conduction condition is met OFF 'The relay does not conduct even if it meets the conduction condition:' In the OFF state, the system flashes and displays' OUT ';


c) Parameter viewing: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system;


d) Display content switching: In the P5 P-6 mode, short press the DOWN key to switch the display content (running time/number of cycles);


Product Size


详情-11


Product Show


主图-00

主图-02

主图-03

主图-04


Payment&Transportation


详情8.1


Official Certificate&Certificate



详情页3.1



Multiple product supply



详情5.1


Company office environment


详情6.1


Warehouse Real Shot


170019007688325e.png


Standard packaging


详情9


We also provide :


Part NoManufacturerDate CodeQuantityDescription
LM22676ADJNS19+250SOP8
TPS562201DDCRTI22+795500SOT23-6
NJG1806K75JRC22+500000DFN6
TLV74318PDQNRTI22+402000X2SON-4
NJG1801K75JRC22+300000SMD
NJG1804K64JRC22+300000DFN8
LM27761DSGRTI22+151000WSON8
TLV62565DBVRTI22+138000SOT23-5
TPS613222ADBVRTI22+108000SOT23-5
LNK625DG-TLPOWER22+100000SOP-8
OPA4322AIPWRTI22+100000TSSOP14
TLV75528PDRVRTI22+99000WSON-6
TPS7A2025PDQNRTI22+78500X2SON-4
TLV62568DBVRTI22+72000SOT23-5
STM32L051K8U6TRST22+60000QFN32
SKY66421-11SKYWORKS22+56500QFN16
TPS7A1111PDRVRTI22+54000WSON6
TLV62569PDDCRTI22+52000SOT23-6
TLV62569DBVRTI22+48000SOT23-5
TPS23753APWRTI22+40000TSSOP14
NB691GG-ZMPS22+30000QFN
SN74AHC1G02DBVRTI22+27939SOT-23
TPS63000DRCRTI22+23238VSON10
TLV75533PDRVRTI22+21500WSON6
NB687BGQ-ZMPS22+20000QFN
A3916GESTR-T-1ALLEGRO22+17150QFN-20
TPS62135RGXRTI22+15000VQFN11
TLE2022AMDRTI0803+12500SOP8
TPS23756PWPRTI22+12000HTSSOP-20


主图-02


主图-03


User Info:
Phone number
+86
  • +86
  • +886
  • +852
Company Name
Email
Product model
Quantity
Comment message